Vacuum Tower: Column Absorber
with Side Draw and Pump Around
Feed: ATM Residue
25 trang |
Chia sẻ: Mr Hưng | Lượt xem: 680 | Lượt tải: 0
Bạn đang xem trước 20 trang nội dung tài liệu Hóa dầu - Vacuum tower, để xem tài liệu hoàn chỉnh bạn click vào nút DOWNLOAD ở trên
Nhóm Mô phỏng Công nghệ Hoá học và Dầu khí
Trường Đại học Bách khoa Hà Nội
VACUUM TOWER
HYSYS Oil-4
Load the Oil-3 and continue
Nội dung
Vacuum Tower: Column Absorber
with Side Draw and Pump Around
Feed: ATM Residue
2 Oil-4
Add a Heater
In this Cell Enter
Connections
Name Vac Heater
Inlet Atm Residue
Outlet Vac Feed
Energy Vac Duty
Worksheet
Pressure, Vac Feed 2.75 kPa (0.4 psia)
Temperature, Vac Feed 395oC (740oF)
3 Oil-4
Add a Heater
4 Oil-4
Add an Absorber Column
Input Expert
Name Vacuum Tower
Stages 9
Bottom Stage Feed Vac Feed
Top Stage Feed Dummy
Overhead Vapour Product Vacuum Ovhd
Bottoms Liquid Vacuum Residue
Optional Side Draw
Name Type Stage
LVGO L 2
HVGO L 6
5 Oil-4
Vacuum Tower
6 Oil-4
Vacuum Tower
7
Vavumn Tower
Top Stage Pressure 1.350 kPa
Bottom Stage Pressure 2.700 kPa
Oil-4
Vacuum Tower
8
Vavumn Tower
Top Stage Temperature 120oC
Bottom Stage Temperature 370oC
Oil-4
LVGO & HVGO Specs
9
The Draw Rate for LVGO = 32 m3/h
Oil-4
LVGO & HVGO Specs
10
The Draw Rate for HVGO = 90 m3/h
Oil-4
Ovhd Vapour Rate Specs
11 Oil-4
The Draw Rate for Vacuum OVHD = 9 kgmole/h
Vavumn Tower
12 Oil-4
Add the Specs
The Draw Rate for Vacuum OVHD = 9 kgmole/h
The Draw Rate for LVGO = 32 m3/h
The Draw Rate for HVGO = 90 m3/h
DOF = -1
Add the Spec for LVGO PA
13 Oil-4
Add Spec to Column
In this cell Enter
Name PA 1
Return Stage 1
Draw Stage 2
Rate 132m3/h
Duty
14
Add PA 1 - LVGO
Oil-4
Delete Stream Dummy - Run
15 Oil-4
Vacuum Tower
Volume Flow Rate of Vacuum Residue = ....?
Volume Flow Rate of Vacuum Ovhd = ....?
Duty of PA 1 = .?
16 Oil-4
Add Pump Around
In this cell Enter
Name PA 2 PA 3
Return Stage 5 8
Draw Stage 6 9
Rate 265 m3/h 330 m3/h
Duty -3.2e7 kJ/h -3.7e7 kJ/h
17 Oil-4
Add Pump Around
18 Oil-4
Vacuum Tower
19 Oil-4
Vacuum Tower
20 Oil-4
Vacuum Tower
Volume Flow Rate of Vacuum Residue = ....?
Volume Flow Rate of Vacuum Ovhd = ....?
Did these values change from before?
Why were the Pump Arounds added then?
Change the Ovhd Temperature:
Top Temperature = 80oC
→ New Ovhd Gas Flow = .?
Save case
21 Oil-4
PFD
22 Oil-4
PFD Column Environment
23 Oil-4
Top Temperature Spec
24 Oil-4
Vacuum Tower
25 Oil-4
Các file đính kèm theo tài liệu này:
- oil4_vacuum_tower_7457.pdf